Oil-lubricated two-stage screw air compressor for standard and medium-pressure plant air.

JYS-HA Standard and Medium Pressure Two-Stage Screw Compressors

Keep 8, 10 or 12.5 bar compressed air steady across long shifts without oversizing the air station. JYS-HA gives standard and medium-pressure plants a two-stage PM VSD compressor range from 37 to 500 kW, helping machining, assembly, automotive and general manufacturing lines match pressure, flow and air treatment in one system plan.
Power range 50โ€“675 HP (37โ€“500 kW)
Pressure Range 8 / 10 / 12.5 bar
Flow Range 5.2-100.0 m3/min
Cooling Type Air Cooling
Drive Type PM VSD
Voltage Options 380V/3PH/50HZ

Built for Standard and Medium-Pressure Industrial Air Demand

The RUEGO JYS-HA Series is an oil-lubricated two-stage screw air compressor for industrial systems that require 8, 10 or 12.5 bar compressed air. The range combines two-stage compression with permanent magnet variable-speed control and covers 37โ€“500 kW with air delivery from 5.2 to 100.0 mยณ/min, depending on model and pressure.

Typical duties include centralized factory air supply, machining and CNC workshops, automotive-component production, electronics manufacturing, general manufacturing and energy-saving replacement projects. Final selection should be based on operating pressure, required flow, load profile, voltage, cooling method, site conditions and downstream air-quality requirements.

RUEGO JYS200HA 160 kW standard and medium-pressure two-stage screw air compressor three-quarter view
JYS200HA shown as a representative 160 kW model in the JYS-HA Series

Why Use Two-Stage Compression with VSD Control?

Pressure Options for Different Industrial Duties

The series covers 8, 10 and 12.5 bar duties so buyers can match the compressor to equipment and pipeline requirements. Air delivery changes with model and pressure, so the rated flow must be confirmed at the selected operating pressure.


Two-Stage Compression for Long Running Hours

Two-stage compression divides the compression duty between two stages to support stable, continuous industrial operation. Actual energy performance still depends on the load profile, operating pressure and complete system design.

Variable-Speed Output for Changing Demand

Permanent magnet VSD control adjusts compressor output to changing air demand, helping reduce unnecessary unloaded operation and pressure fluctuation in systems with variable consumption.


Cooling and Maintenance by Project Condition

Cooling can be air-cooled or water-cooled according to the model and project. Ventilation, cooling-water conditions, foundation capacity, electrical supply, maintenance clearance and ambient temperature should be confirmed before the final configuration is approved.

Where JYS-HA Fits, and What to Confirm

JYS-HA is intended for standard and medium-pressure industrial air systems. Confirm the pressure and air-quality requirement at the point of use before choosing the series.

Suitable Applications

  • Centralized factory air stations serving multiple production lines.
  • Machining, CNC, automotive-component and general-manufacturing systems with 8โ€“12.5 bar demand.
  • Long-running or variable-demand systems being evaluated for VSD replacement.

Conditions to Confirm Separately

  • For confirmed 5 bar low-pressure large-flow duty, compare the JYS-HL low-pressure series.
  • If the process requires oil-free air, choose an oil-free compressor; downstream treatment does not make an oil-lubricated compressor oil-free.
  • Laser-cutting auxiliary air requires equipment-specific pressure and air-quality confirmation; JYS-HA is not a dedicated laser-cutting series.

A two-stage VSD compressor is not automatically the most efficient choice for every plant. The result depends on pressure, flow, operating hours, load variation, piping and downstream treatment.

Plan the Complete Industrial Compressed Air System

Compressor selection should be reviewed together with the distribution network and downstream treatment:

  • Size piping for rated flow, distance, simultaneous demand and acceptable pressure drop.
  • Use an air receiver when demand changes require additional buffering and pressure stability.
  • Add a refrigerated air dryer for general moisture control, or confirm a desiccant dryer when a lower pressure dew point is required.
  • Select precision filters and automatic drains for the required oil, particle and condensate control.
  • For water-cooled models, confirm cooling-water flow, temperature, pressure, water quality and circulation conditions.

For a broader comparison of pressure ranges and two-stage configurations, review the two-stage screw air compressor series before confirming the final project specification.

RUEGO JYS50HA 37 kW two-stage screw air compressor open-cabinet internal structure view
Representative JYS50HA 37 kW internal view; downstream treatment and piping are configured separately

Need help selecting your model?

Our team is ready to provide professional advice for your compressed air system.

Related products

RUEGO Small Series tank-mounted compact screw air compressor front view

Oil-lubricated screw air compressor

Small Rotary Screw Air Compressor with Tank

Power
3-10 HP

Pressure
8-10 bar

Flow
0.27-1.1 m3/min

RUEGO JYS300HL 220 kW 5 bar low-pressure large-flow two-stage screw air compressor, side three-quarter view

Two Stage Rotary Screw Air Compressor

5 Bar Low Pressure Screw Compressor

Power
50โ€“300 HP (37โ€“220 kW)

Pressure
5 bar

Flow
8.2-63.0 mยณ/min

JCG20 integrated screw air compressor with dryer and tank three-quarter view

Oil-lubricated VSD screw air compressor

JCG Series Rotary Screw Air Compressor with Dryer and Tank

Power
20-50 HP

Pressure
16 bar

Flow
1.62โ€“3.99 mยณ/min

RG75HPM 55kW VSD screw air compressor front view

Oil-lubricated VSD screw air compressor

RG Series Variable Speed Rotary Screw Air Compressor

Power
10-350 HP

Pressure
8 / 10 / 12 bar

Flow
0.72-42.3 mยณ/min

Scroll to Top

Request a Quote

Tell us which products you need and your requirements. Our team will help with selection and prepare a quotation.

Include the product or model, quantity, application and any specifications you know.

Air compressor inquiry

Request a Quote

Share your requirements for this product. Our team will review the configuration and prepare a quotation.

Include the model or required airflow, working pressure, power supply and quantity, if known.

Sending your inquiryโ€ฆ

Thank you. Your compressor requirements have been sent.